Sök:

Sökresultat:

9060 Uppsatser om Geothermal heat pump system - Sida 1 av 604

Frånluftsvärmepumpens möjligheter i flerbostadshus

If a building is heated by a heat pump, it is of high importance that the heat pump has a high coefficient of performance. An exhaust air heat pump extracts heat from the building?s exhaust air. The air has a relatively high and constant temperature all year around, leading to a high seasonal coefficient of performance. This thesis examines whether it is profitable to complement an exhaust ventilation system with an exhaust air heat pump in an apartment block that already has geothermal heat pump, district heating, oil- or biofuel heated system.

Projektering av ett småhus samt ekonomisk jämförelse av värmesystem

Design of a house requires knowledge of both technology and economics. Heating and ventilation shall be designed, costs are calculated and estimated and requirements must be fulfilled. Which heating system is to be elected is also a difficult choice, especially with rising energy prices as a factor.The choice of energy system is not always given, because it depends on several factors. Below is a comparison between district heating, geothermal heat pump and electric boiler from an economic standpoint. In a previous report appears district heating and geothermal heat pump as the best options.

Studie av skyddsavstånd mellan bergvärmeanläggning och skyddsobjekt i ett vattenskyddsområde

During installation and operation of a Geothermal heat pump system leakage of an antifreezing agent can appear in a borehole and leak out in surrounding groundwater. To guarantee high quality drinking water for generations to come Sweden has dedicated some areas as water protection areas. The local authority gives permits for the installation of heat pump systems within water protection areas. Before giving a permit the local authority makes an evaluation of the risks involved in installation and operation of the system within the area. By keeping a certain distance between the protected object in the area and the heat pump system the risk of polluting the protected object with an anti-freezing agent can be reduced.This thesis makes a comparison between three different methods of calculating an appropriate distance between the protected object and the heat pump system.

Solmodul jord- och bergvärmepump

An increasing number of heat pump producers have developed heat pumps that can be connected to solar panels. In this thesis we have examined the possibilities of connecting solar panels to existing ground source- and geothermal heat pumps that has not been adapted to solar panels. During the work process, a prototype plant has been built to compare our theory with the practical results and with our designed sizing tool. The work has rendered in knowledge that will be used to build a sun module that can be easily connect to the existing heat pump system. The existing heat pump, our test plant, has been supplemented by an advanced storage tank used to allow different operating modes.

Prestandaförändringen hos en bergvärmeanläggning efter fem års drifttid

The aim of this report was to do a case study at a geothermal heating system which has been in operation for about 5 years, and study if its performance has changed during this period of time. A literature study about the processes involved was also done in purpose of background knowledge.The tenant-owner?s association Duvan at Petterslundsgatan in Uppsala installed year 1999-2000 a geothermal heating system. The purpose of this installation was that they hoped it would lead to a smaller usage of district heating which would lead to a reduction of the heating expenses for their buildings. The geothermal heating system consists of 19 energy wells and 4 geothermal heat pumps, and it is one of the first systems of that size in the region of Uppsala.

Bergkyla och bergvärmeutredning för industrilokalen Rödbergsmyran 5 i Umeå, Västerbotten.

Grubbe Ventilation AB is a sheet metal and ventilation company who provides design, installation, service, and repair of ventilation. The company is expanding their business by building a new facility in Umeå, Västerbotten. The property is designed to be used for both office and industrial work.Grubbe Ventelation AB has not yet decided upon wish system which is to be established to provide the building with heating and cooling. The consulting firm Umeå Projekt Team has therefore been asked to investigate the possibilities to invest in geothermal- heating and cooling.If the investigation of a geothermal heating- and cooling system would provide favorable results it would be a very appropriate alternative that provides energy at low costs and are an environmentally friendly option as the energy comes from stored solar energy in the ground is provided by stored solar energy in the ground.The facility ´s heating and cooling consumptions are calculated in the program BV2 and the result indicate a heating demand of 185 000 kWh per year due to thermal transmittance, transmission losses, heating of warm water and a cooling requirement of 5500 kWh.Three different systems of geothermal heating and cooling were tested in the computer program Energy Earth Design. The results show no difference in the dimensioning of the drill hole if merely heating were to be used or both heating and cooling were to be established.

Luft/luftvärmepump : - Med möjlighet till återvinning

Sweden has long had access to low electricity prices due to the wide availability of hydro and nuclear power. This has now changed because of today's rising electricity rates resulting in increasing heating costs for properties, especially in the properties with electric heating systems."Ankaret" is a parish for "Svenska Alliansmissionen", which is located at "Gullbrannagården".The parish has installed electrical radiators and an exhaust ventilation system that makes the energy demand high due to the large ventilation flows. The building was built as the price of electricity was still low and would reduce energy use today by combining its heating system with an air/air heat pump. The heat pump delivers more heat into the room than the electrical energy that it uses. This lowers the electricity needs.

Jämförelse av frånluftsvärmepumpar

In order to reach the environmental targets, set up by the EU, there are many measures taken to make Sweden more energy efficient. In the housing and real estate sector, an installation of an exhaust air heat pump that reuses the heat in the exhaust air in order to lower the amount of acquired energy, is an example of such an action. The recovered energy can then be used for heating of radiators and tap water. This report aims to evaluate and compare three different systems using exhaust air heat pumps regarding COP, degree of coverage and cost savings. This study was delimited to only account for apartment buildings.The theory chapter describes the different conditions and factors that affect a building?s energy balance.

Utvärdering av ett större bergvärmesystem i en flerbostadsfastighet som har konverterats från fjärrvärme

This master thesis is an in-depth study of an existing heating system at a household cooperative in Uppsala that has been converted from district heating to a bedrock heat pump system. The study focuses on an economical system optimisation of the building?s complete heating system. The aim was to determine how well a heat pump system in large buildings actually work, find out possible ways to optimize the existing system and point out important system parameters for new heat pump installations in larger buildings.The project points out a possible energy cost reduction of 45 % without investment and further cost reductions with equipment investments. A reduction by 30 % is possible by improvements in the regulation system and 15 % is possible by maintaining the brine system.

En kombinerad Organisk Rankinecykel och värmepump integrerat med ett fjärrvärmesystem : Där värme- och elproduktion samt lönsamhet studeras och avfall är huvudbränslet

The demand for district heating is expected to decrease in the future, due to competition from heat pumps and energy efficiency measures in buildings. Development of existing district heating systems is therefore necessary for district heating companies to maintain market shares. This Master?s thesis describes and investigates the heat and electricity production and profitability of a combined Organic Rankine Cycle (ORC) and heat pump that is integrated with an existing district heating system. The studied district heating system is utilizing heat from waste incineration. In Sweden waste constitute 20 % of the fuel mix used in district heating systems, and this share is expected to increase in the future.

Konvertering från direktverkande el i kommersiella lokaler : Ekonomisk och hållbar utveckling

Buildings worldwide account for 40 % of the total energy use. Climate change is of increasing importance, but few are willing to reduce their standard of living or get a higher cost for the change. Energy efficiency of existing buildings gives the greatest benefit economically and environmentally. The real estate company Klövern AB manages 46 properties in Karlstad. Heating is the major cost of the total operating costs of real estate. Rising energy prices increase the need for Klövern AB to improve energy efficiency and to investigate alternative sources of heat.

Ljudreducering av värmepump

This degree project handles acoustic measurements of the heat pump EcoAir 107, made by Enertech CTC AB. The sound from the three sound sources of the heat pump, fan, compressor and four way valve, have been measured to find out how they affect the total sound level of the product.Measures to attenuate the sound level have been developed and tested. By comparing these with the sound of the heat pump, in its original state, we have found out the measures which have best effects.The best attenuating measures came to be: taped openings and holes around the compressor space, isolating the top and the bottom of the whole construction, support of the fan bottom part and shielding of the sound source with a screen at a distance of 110 mmThese measures have been tested together and an average attenuation of the total sound level with 3,9 dB have been accomplished. In the front of the fan where the continuous sound is the strongest, the attenuation was 4,7 dB.This project is meant to be used as a guide by Enertech CTC AB:s during their future developing process..

Hur byggnadsdetaljer ändrar fasadens uttryck

An energy study has been performed on two blocks in an area called Gävle Strand. The buildings are owned by a tenant-owner?s association called brf Carolina and were built by the company Skanska 2008. The builder as well as brf Carolina are pussled by the fact that electricity use is higher than expected while heating is less. Skanska is also very interested in finding out how much heat recovery from stale exhaust air through a geo-thermal heat pump is contributing to the general heating requirement and energy balance in four out of the ten buildings located on the properties.To find possible answers to the higher electricity use a literature survey on user behaviour was conducted.

Skalkonstruktion : Med inriktning mot hållfasthet och dämpning av ljud

The sound part is mainly practical and is dependent on concepts that have been tested through measuring with a sound level meter. The design part is more theoretical and has been verified with CAD models and finite element analysis.With a sound damping hood on the compressor the sound level is reduced with up to four dB. An optimized absorbent for the compressor space gives a reduction with three dB. By using the insulation for the heat water tank as absorbent we can see a sound reduction on the lover octave bands. A reduction like this is elsewhere hard to achieve as at it requires thick absorbents.By changing the today?s insulation to the heat water tank to a form of polystyrene polymer insulation the weight from the heat pump above can be transferred to the stable heat water tank.

Uppvärmd konstgräsplan : Beräkning av utnyttjningstid för en uppvärmd konstgräplan med alternativa rörplaceringar

For Skattkärr IF a turf field with warming has been projected to increase field?s utilization hours and to have a longer period for athletes to perform their activities outdoors. The technique chosen to heat the plan is a type of a geothermal heating system without a heat pump. The brine, which is water with 30% ethanol, collects heat from the borehole and discharges it to a coil in the field. There is at position 11 boreholes but it is planned to increase the number to 31, which is the design for the facility.

1 Nästa sida ->